10715 Se 256Th St, Kent WA 98030 · License #626947 · Center · Child Care Center
Not published by the state. Owners can add hours via profile claim.
When they operate
Ages served
110-300-0146(1)(a)(b) · Playground equipment and surfacing used by an early learning provider must comply with applicable CPSC guidelines, as now and hereafter amended including, but not limited to, installing, arranging, designing, constructing, and maintaining outdoor play equipment and surfacing. (a) Climbing play equipment must not be placed on or above concrete, asphalt, packed soil, lumber, or similar hard surfaces;(b) The ground under swings and play equipment must be covered by a shock absorbing material (grass alone is not an acceptable) such as: (i) Pea gravel at least nine inches deep; (ii) Playground wood chips at least nine inches deep; (iii) Shredded recycled rubber at least six inches deep; or (iv) Any material that has a certificate of compliance, label, or documentation stating it meets ASTM standards F1292.
The play structure lacked a 6-foot fall zone on all sides. Additionally, the minimum clearances of 20"between swings for "Single-Axis Swings" were not followed. The play structure built in the outdoor area does not comply with CPSC installation and layout standards and arranging
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0460(2) · Each child's enrollment record must include the following: (a) The child's birth date; (b) An enrolled child’s parent or guardian's phone numbers, address, and contact information for reaching the family while the child is in care; (c) Emergency contact information. If no emergency contact is available, a written and signed emergency contact plan may be accepted; (d) Names and phone numbers of persons authorized to pick up enrolled children; (e) A plan for special or individual needs of the child, if applicable, including parent or guardian signature, pursuant to WAC 110-300-0300; (f) Signed parent or guardian permissions, pursuant to WAC 110-300-0450 as applicable for: (i) Field trips; (ii) Transportation; (iii) Bathing; (iv) Water activities including swimming pools or other bodies of water; and (v) Photo, video, or surveillance activity. (g) The beginning and end enrollment date for children no longer in the early learning program’s care; (h) Physical restraint documentation pursuant to WAC 110-300-0335, if applicable; (i) Expulsion information, documentation, and steps taken to avoid expulsion, if applicable; (j) Termination of services documentation and communication, if applicable; and (k) Notification of child developmental screening information given to the child’s parent or guardian, if applicable.
Generated from this facility's specific inspection record
Data synced from Washington State Department of Children, Youth & Families on Jul 9, 2026 · Source records · Report an error
Child 1 is missing emergency contact information. If no emergency contact is available, a written and signed emergency contact plan may be accepted. Signed parent or guardian permissions pursuant to WAC 110-300-0450
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0166(3)(b) · To ensure a safe exit from the premises during an emergency, early learning providers must comply with the following requirements: (b) Exit doors that are not designated as an emergency exit door may be locked during operating hours. Locking interior doors in early learning program space must be designed to be unlocked from either side. An unlocking device must be readily available; and
110-300-0165( 3) (a) (b) The front and back door that is designated for an emergency exits were locked with a chain link lock up on the top. Supervisor observed a teacher place the chain lock on the door after a parent exited the front door.
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0145(11) · Prior to licensing, exiting mechanisms on gates from a licensed outdoor play area to unlicensed space must be equipped with a self-closing and self-latching mechanism (shuts automatically when released from an individual’s control). A gate that is not an emergency exit must be locked or self-closing and self-latching.
110-300-0145(11) one of the emergency exits outside does not self-latch when released from an individual's control. Risk WAC/RCW
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0165(2)(d) · An early learning provider must take steps to prevent hazards to children including, but not limited to: (d) Making inaccessible to children plastic bags and other suffocation hazards;
110-300-0165(2) (d) an open box of latex gloves were observed on the lower shelf of the diaper changing table accessible the infants in the classroom. 110-300-0165( 3) (f) a small refrigerator placed on a shelf posed a tipping hazard accessible to children.( refrigerator was moved during visit) Risk WAC/RCW
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0165(3)(f) · An early learning provider must take measures intended to prevent other hazards to children in care in early learning program space including, but not limited to: (f) Falling objects. Large objects that pose a risk of falling or tipping must be securely anchored. Large objects include, but are not limited to, televisions, dressers, bookshelves, wall cabinets, sideboards or hutches, and wall units;
110-300-0165(2) (d) an open box of latex gloves were observed on the lower shelf of the diaper changing table accessible the infants in the classroom. 110-300-0165( 3) (f) a small refrigerator placed on a shelf posed a tipping hazard accessible to children.( refrigerator was moved during visit) Risk WAC/RCW
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0166(3)(a) · To ensure a safe exit from the premises during an emergency, early learning providers must comply with the following requirements: (a) Emergency exit doors must remain unlocked from the inside, but may be locked from the outside while the early learning program is open. The door handle must be of the type that can be opened from the inside without the use of a key, tools, or special knowledge, and must automatically unlock when the knob or handle is turned;
110-300-0165( 3) (a) (b) The front and back door that is designated for an emergency exits were locked with a chain link lock up on the top. Supervisor observed a teacher place the chain lock on the door after a parent exited the front door.
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0165(5)(b) · To ensure a safe environment for children in care, an early learning provider must comply with the following electrical requirements: (b) Outlets near sinks, tubs, toilets, or other water sources must be inaccessible to children or be tamper-resistant and equipped with a ground fault circuit interrupter (GFCI) outlet type;
0165(5)(a) - Outlet in toddler room(2) must be tamper resistant. 0165(5)(a) - Outlet in preschool room (2) must be tamper resistant. 0165(5)(b) - Outlet in bathroom is GFCI but not tamper resistant. Must be both or can be covered with a blank plate. 0165(3)(e) - Water hoses(2) laying on ground outside are tripping hazards. 0165(3)(f) - Diaper changing tables in the infant and todller rooms are tipping hazards as the wheels don't lock.
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0215(3)(c) · Medication must be stored and maintained as directed on the packaging or prescription label, including applicable refrigeration requirements. An early learning provider must comply with the following additional medication storage requirements: (i) Medication must be inaccessible to children; (ii) Controlled substances must be locked in a container or cabinet which is inaccessible to children; (iii) Medication must be kept away from food in a separate, sealed container; and (iv) External medication (designed to be applied to the outside of the body) must be stored to provide separation from internal medication (designed to be swallowed or injected) to prevent cross contamination.
Need a locked box for controlled substances. Risk WAC/RCW
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0146(1)(a)(b) · Playground equipment and surfacing used by an early learning provider must comply with applicable CPSC guidelines, as now and hereafter amended including, but not limited to, installing, arranging, designing, constructing, and maintaining outdoor play equipment and surfacing. (a) Climbing play equipment must not be placed on or above concrete, asphalt, packed soil, lumber, or similar hard surfaces;(b) The ground under swings and play equipment must be covered by a shock absorbing material (grass alone is not an acceptable) such as: (i) Pea gravel at least nine inches deep; (ii) Playground wood chips at least nine inches deep; (iii) Shredded recycled rubber at least six inches deep; or (iv) Any material that has a certificate of compliance, label, or documentation stating it meets ASTM standards F1292.
Small outdoor climber has 2" of ground cover. Must be at least 9".
Open Not marked corrected in the state record
Open / not marked corrected.