Kennewick WA 99336 · License #wa0018y000006unWjAAI · Home-based · Family Child Care Home
When they operate
Ages served
110-300-0146(1)(a)(b) · Playground equipment and surfacing used by an early learning provider must comply with applicable CPSC guidelines, as now and hereafter amended including, but not limited to, installing, arranging, designing, constructing, and maintaining outdoor play equipment and surfacing. (a) Climbing play equipment must not be placed on or above concrete, asphalt, packed soil, lumber, or similar hard surfaces;(b) The ground under swings and play equipment must be covered by a shock absorbing material (grass alone is not an acceptable) such as: (i) Pea gravel at least nine inches deep; (ii) Playground wood chips at least nine inches deep; (iii) Shredded recycled rubber at least six inches deep; or (iv) Any material that has a certificate of compliance, label, or documentation stating it meets ASTM standards F1292.
0146(1)(a)(b) The individual swing was not meeting CPSC guidelines. The use zone around the equipment did not extend 6 feet out. This poses a falling hazard on hard surface and not shock absorbing material.
Open Not marked corrected in the state record
Open / not marked corrected.
Generated from this facility's specific inspection record
Data synced from Washington State Department of Children, Youth & Families on Jul 9, 2026 · Source records · Report an error
110-300-0146(1)(a)(b) · Playground equipment and surfacing used by an early learning provider must comply with applicable CPSC guidelines, as now and hereafter amended including, but not limited to, installing, arranging, designing, constructing, and maintaining outdoor play equipment and surfacing. (a) Climbing play equipment must not be placed on or above concrete, asphalt, packed soil, lumber, or similar hard surfaces;(b) The ground under swings and play equipment must be covered by a shock absorbing material (grass alone is not an acceptable) such as: (i) Pea gravel at least nine inches deep; (ii) Playground wood chips at least nine inches deep; (iii) Shredded recycled rubber at least six inches deep; or (iv) Any material that has a certificate of compliance, label, or documentation stating it meets ASTM standards F1292.
The wood chips under the play set only measuring 3 inches. It needs to measure to 9 inches of depth. WAC/RCW Correction Date Disputed Date Disputed 110-300-0166(3)(a) Serious
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0166(3)(a) · Non-Compliances: This section of the Inspection Report lists non-compliances found during any licensing inspection. Information from this section will be reported to Child Care Check and be can be used to determine current and future licensing and enforcement actions. To ensure a safe exit from the premises during an emergency, early learning providers must comply with the following requirements: (a) Emergency exit doors must remain unlocked from the inside, but may be locked from the outside while the early learning program is open. The door handle must be of the type that can be opened from the inside without the use of a key, tools, or special knowledge, and must automatically unlock when the knob or handle is turned;
0166(3)(a) The emergency door that leads to the outdoor play area was locked.
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0145(11) · Prior to licensing, exiting mechanisms on gates from a licensed outdoor play area to unlicensed space must be equipped with a self-closing and self-latching mechanism (shuts automatically when released from an individual’s control). A gate that is not an emergency exit must be locked or self-closing and self-latching.
There has been a fence added in front of the self closing self latching gate outside. WAC/RCW Correction Date Disputed Date Disputed 110-300-0165(3)(a) Short Term
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0165(3)(a) · An early learning provider must take measures intended to prevent other hazards to children in care in early learning program space including, but not limited to: (a) Cuts, abrasions, and punctures. Equipment, materials, and other objects on the premises that have splintered edges, sharp edges, points, protruding nails, bolts, or other dangers must be repaired, removed, or made inaccessible to children; Non-Compliances: This section of the Inspection Report lists non-compliances found during any licensing inspection. Information from this section will be reported to Child Care Check and be can be used to determine current and future licensing and enforcement actions.
0165(2)(c)There were hanging ropes from a tree capable of forming a loop around a child's neck. 0165(3)(a)There is a sharp knife in the drying rack accessible to children. 0165(3)(a)The new fence needs to be sanded down because it poses splinter hazards WAC/RCW Correction Date Disputed Date Disputed 110-300-0166(3)(a) Serious
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0166(3)(a) · To ensure a safe exit from the premises during an emergency, early learning providers must comply with the following requirements: (a) Emergency exit doors must remain unlocked from the inside, but may be locked from the outside while the early learning program is open. The door handle must be of the type that can be opened from the inside without the use of a key, tools, or special knowledge, and must automatically unlock when the knob or handle is turned;
The emegency door leading to the outside was locked during today's visit. WAC/RCW Correction Date Disputed Date Disputed 110-300-0260(1)(a) Serious
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0260(1)(a) · An early learning provider must ensure all poisonous or dangerous substances including, but not limited to fuels, solvents, oils, laundry, dishwasher, other detergents, sanitizing products, disinfectants and items labeled “keep out of reach of children” are stored: (a) In a location that is inaccessible to children;
There were two tubes of disinfecting wipes underneath handwashing sink in bathroom that were accessible to children. Garage door was unlocked from inside the home and children also had access to the garge door through the outside becuase it was also unlocked. WAC/RCW Correction Date Disputed Date Disputed 110-300-0260(2)(a)(b) Serious
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0260(2)(a)(b) · Non-Compliances: This section of the Inspection Report lists non-compliances found during any licensing inspection. Information from this section will be reported to Child Care Check and be can be used to determine current and future licensing and enforcement actions. Storage areas and storage rooms must: (a) Be inaccessible to children; (b) Have locking doors or other methods to prevent child access;
There were two tubes of disinfecting wipes underneath handwashing sink in bathroom that were accessible to children. Garage door was unlocked from inside the home and children also had access to the garge door through the outside becuase it was also unlocked. WAC/RCW Correction Date Disputed Date Disputed 110-300-0165(2)(c) Short Term
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0165(2)(c) · An early learning provider must take steps to prevent hazards to children including, but not limited to: (c) Making inaccessible to children straps, strings, cords, wires, or similar items capable of forming a loop around a child’s neck that are not used during supervised early learning program activities;
0165(2)(c)There were hanging ropes from a tree capable of forming a loop around a child's neck. 0165(3)(a)There is a sharp knife in the drying rack accessible to children. 0165(3)(a)The new fence needs to be sanded down because it poses splinter hazards WAC/RCW Correction Date Disputed Date Disputed 110-300-0345(5)(b) Short Term
Open Not marked corrected in the state record
Open / not marked corrected.
110-300-0345(5)(b) · An early learning provider must: (b) Be able to hear when doors in the immediate area are opened to prevent children from leaving unsupervised;
When this licensor arrived, Ma answered the door on the main level but the children were on the lower level in the main daycare room. There is no alarm on the back door to prevent children from leaving unsupervised.
Open Not marked corrected in the state record
Open / not marked corrected.