19150 Helena Ave, Pt Charlotte FL 33948 · License #C20CH0027 · Center · Child Care Facility
When they operate
Ages served
Ages not published.
32-07 · Outdoor Equipment
At the time of the inspection, the Licensing Specialist observed the fall zone under the slide of the large climbing equipment did not extend in all directions for 6 inches for 6 feet. The Licensing Specialist took pictures will a ruler showing the depth. The Licensing Specialist provided technical assistance from the handbook 3.12. D. Permanent or stationary playground equipment must have a fall/use zone that extends a minimum of 6 feet in all directions from the perimeter of the equipment. All types of ground cover must be maintained to provide resilience and reduce the incidence of injuries to children in the event of falls. 1. If the ground cover in place is loose ground cover (such as, but not limited to: mulch, shredded rubber chips, or sand) a minimum of 6 inches in depth is required in the use zone. Asphalt,concrete, hard packed dirt, hay, grass or leaves are unsuitable for use in the use zone area. 2. If the ground cover in place is a unitary playground surface, then the unitary surfacing materials must be installed, maintained, or replaced according to manufacturers instructions. Unitary surfaces must be tested to and comply with ASTM F1292; documentation of test data must be retained at the facility and available for licensing to review. 3. If the play area was approved by the Department prior to January 1, 2020 and does not meet the 6-foot fall/use zone requirement, then the facility must submit a written notification, including photographs and layout of the play area, to the Department prior to or on April 1, 2020, notifying its intention to continue to operate using the prior approved play area. However, if the permanent or stationary playground equipment is moved or replaced then the standard would apply, and 6 feet of use zone must be provided. Any new equipment added would be required to have the 6 feet of use zone in all directions from the perimeter of the equipment
Generated from this facility's specific inspection record
Data synced from Florida DCF, Office of Child Care Regulation on Jul 8, 2026 · Source records · Report an error
Open Not marked corrected in the state record
Category: health medication. Open / not marked corrected.
45-05 · Background Screening Documents
At time of the inspection, the Licensing Specialist observed one staff records did not have documentation of five years of employment history in the file. The Licensing Specialist took pictures. The Licensing Specialist provided technical assistance from the handbook 5.1, D The employer/owner/operator must conduct employment history checks, including documented attempts to contact each employer that employed the individual within the preceding five years, and documentation of the findings. Documentation must include the applicants job title and description of his/her regular duties, confirmation of employment dates, and level of job performance. The employer/owner/operator must make at least three attempts to obtain employment history information. Failed attempts to obtain employment history must be documented in the personnel file and include date, time, and the reason the information was not obtained
Open Not marked corrected in the state record
Category: background checks. Open / not marked corrected.
13-02 · Toxic Substances, Hazardous Materials and Weapons
At the time of inspection, the counselor observed bottles of sanitizer wipes stored in the two bottom drawers of an unlocked file cabinet, in an unlocked closet in the classroom accessible to children. Pictures taken. The director moved the bottles and placed them on the high shelves in the closet bringing the center back into compliance immediately. Provided technical assistance from the handbook 3.2 B 3.2 Toxic/Hazardous Material/Firearms/Weapons B. All potentially harmful items, including cleaning supplies, flammable products, poisonous, toxic, and hazardous materials, must be labeled and used according to manufacturers recommendation. These items, as well as knives, sharp tools, and other potentially dangerous hazards, must be stored in a locked area or must be inaccessible and out of a childs reach at all times
Corrected Corrected by Mar 26, 2024
Category: nutrition. Marked corrected in the state record.
17-07 · Outdoor Play Area/Fencing
At the time of the inspection, the counselor observed the right-hand fence near the gate area upon entering had a gap at the bottom so it was not at ground level. en out. The gap measured more than 3 and half inches. Pictures taken. Provided technical assistance from the handbook 3.5 F. The outdoor play area must have adequate fencing or walls a minimum of 4 feet in height. Fencing, including gates, must be continuous and must not have gaps or opening larger than 3 inches that would allow children to exit the outdoor play area. The base of the fence must remain at ground level and be free from erosion or buildup to prevent inside and outside access by children or animals. These areas must have at least two exits, with at least one being remote from the buildings. If an outdoor play area was approved for usage by the Department prior to October 25, 2017, no new exits are required to be added to meet this standard. However, if outdoor play area fencing is changed then the standard would apply, and two exits must be provided
Open Not marked corrected in the state record